Available in residential diameters 4″ – 8″. Additional sizes available up to 24″. Pellet venting systems for gas, wood pellet, and bio- fuels.

What diameter is B vent?

Available in residential diameters 4″ – 8″. Additional sizes available up to 24″. Pellet venting systems for gas, wood pellet, and bio- fuels.

What is the outside diameter of 3 B vent?

Dimensions and Measurements

Height 12 in.
Outer Pipe Gauge 28
Pipe Inside Diameter 3 in.
Product Weight 6 lbs.
Vent Pipe Size 3

What is the outside diameter of a 6 inch B vent?

Dimensions and Measurements

Height 12 in.
Inner Pipe Gauge 28
Length 10, 3 in.
Outer Pipe Gauge 28
Pipe Inside Diameter 6 in.

What is the outside diameter of 4 inch B vent?

4.5 Inch
Gas Vent Pipe; Type Type B Gas Vent, Double Wall, Round; Size 4 Inch Inner Diameter x 4.5 Inch Outer Diameter; Length 36 Inch; End Type Lock Ring; Material Thickness 0.012 Inch (Inner Wall), 0.018 Inch (Outer Wall); Material Aluminum (Inner Wall), G90 Galvanized Steel (Outer Wall); Temperature Rating 400 Deg F; …

Can you install B vent through wall?

Any portion of your B vent system that passes through the occupied area must be enclosed to protect against any emergency, such as the system’s burning. But we will not recommend installing the B vent pipe on the outside wall of the building, especially when the outside weather is cold.

What is the outside diameter of 8 B vent?

Gas Vent Pipe; Type Type B Gas Vent, Double Wall, Round; Size 8 Inch Inner Diameter x 9 Inch Outer Diameter; Length 60 Inch; End Type Lock Ring; Material Thickness 0.012 Inch (Inner Wall), 0.018 Inch (Outer Wall); Material Aluminum (Inner Wall), G90 Galvanized Steel (Outer Wall); Temperature Rating 400 Deg F; …

What is the outside diameter of a 5 in B vent pipe?

Dimensions and Measurements

Height 12 in.
Inner Pipe Gauge 28
Length 10, 3 in.
Outer Pipe Gauge 28
Pipe Inside Diameter 5 in.

Can B vent touch drywall?

Drywall and wallboard are considered combustible materials and should not be installed against the vent including the use of this material to close off the hole around the vent. Type B Gas Vent requires a minimum of one-inch clearance to combustibles.

Can B Vent be run horizontally?

The Type B or single-wall vent connector cannot be installed horizontally. But it can be run almost horizontally: 1/4” per foot slope upward toward the vent, with no dips or sags, per International Residential Code (IRC G2427. 10.7). The vent it connects to must terminate vertically.

Is B vent stainless steel?

Both are double-walled, although Type L vents generally have a stainless steel inner wall, while Type B vents do not.

Can B Vent be used horizontally?

How close can b vent be to wood?

one-inch
Type B Gas Vent requires a minimum of one-inch clearance to combustibles. This one-inch is a typical clearance for all brands of Type B Vent, but each section of vent pipe is marked with the clearance required by Underwriter Laboratories, so it should be checked.