There is no Code requirement calling for this bonding conductor(s) to be installed “in one continuous length without a splice or joint.” This would be true if this conductor were a grounding electrode conductor [see 250.64(C)], but this conductor is not a grounding electrode conductor (used for grounding), it is a …

Does pool bonding wire have to be continuous?

There is no Code requirement calling for this bonding conductor(s) to be installed “in one continuous length without a splice or joint.” This would be true if this conductor were a grounding electrode conductor [see 250.64(C)], but this conductor is not a grounding electrode conductor (used for grounding), it is a …

What is the code for grounding a pool?

The grid must be constructed of minimum 8 AWG bare solid copper conductors bonded to each other at all points of crossing, and the grid must conform to the pool’s shape, as well as be secured within or under the pool no greater than 6 inches from the outer contour of the pool’s shell.

What year did pool bonding become code?

Pool Electric Codes Passed in 1968, the “Swimming Pool Code” applies to new construction and reconstruction, for all equipment in the image above. In other words, all electrical equipment must comply with the provisions of the National Electric Code; Article 680, and not just pool lighting.

How deep should pool bonding wire be?

Non-conductive pool shells must have a #8 (or larger) solid copper wire buried 4” – 6” below finished grade with such bond wire placed from18” – 24” from the inside pool wall around the pool, (equipotential bonding) that which starts and returns/ terminates at the pool pump.

What happens if a pool is not bonded?

If you do not bond your pool equipment there is the risk that the equipment itself will become the anode in a galvanic couple with other metal components in or around your pool. If this happens, the anode metals will deteriorate at an advanced rate, a phenomenon called galvanic corrosion.

Do you need a ground rod for a pool?

YOU DO NOT NEED TO INSTALL GROUND RODS OR RUN THE #8 BONDING CONDUCTOR BACK TO THE SERVICE OR SUB PANEL.

How do I know if my pool is bonded?

Look for an exposed copper wire attached to the motor and pumps, going into the ground. It should connect in a similar way as in the image to the left. If you live in a municipality, you can also contact the building and inspection department to see if your pool had a code inspection during its construction.

What is pool bonding?

Bonding is the process by which the electrical and metallic components of the pool are joined together with a wire to form a non-resistive path between the components. The goal of bonding is to connect, contain and prevent the transmission of any harmful electrical voltage to pool equipment, people and pets.

How do I know if my inground pool is bonded?

Does pool bonding need a ground rod?

Does a pool pump need a GFCI breaker?

The National Electric Code requires that all swimming pool pumps be connected to a GFCI breaker.

What is article 680 of the California Code of electrical regulations?

The requirements contained in Article 680 apply to the installation of electrical wiring and equipment for swimming pools, spas, hot tubs, fountains, and hydromassage bathtubs. The overriding concern of this article is to keep people and electric- ity separated.

What are the requirements for Part I of Article 680?

The requirements contained in Part I of Article 680 include the locations of switches, receptacles, and luminaires. Figure 680–48 Figure 680–49 FREE PDF Pools and Similar Installations 2014 EC 22www.MikeHolt.com 888.NEC.CODE (632.2633) Article 680 Swimming Pools, Spas, Hot Tubs, Fountains, and Similar Installations

What is article 680 of the OSHA code for pools?

Article 680 Swimming Pools, Spas, Hot Tubs, Fountains, and Similar Installations (5) The bonding conductor must be secured in or under the deck or unpaved surface within 4 in. to 6 in. below the subgrade. (3) Metallic Components.

What does the 2020 NEC edition of NFPA 70 include?

Once there, click on their link to free access to the 2020 NEC edition of NFPA 70. 680.26 (B) (2) Perimeter Surfaces. The perimeter surface to be bonded shall be considered to extend for 1 m (3 ft) horizontally beyond the inside walls of the pool and shall include unpaved surfaces and other types of paving.

https://www.youtube.com/watch?v=j7r1UyuIgss